CM-150 Screen Centering Microscope for Lab Centration Inspection
Instrument Features High accuracy. 15″ per division. Fixed reticle graduation. The reticle graduation of the instrument is always maintained at 15″ per division…
View details →ATS series includes ATS100 & ATS300
ATS100 includes ATS112, ATS113, ATS124
◆ Unique optical design, extra long working distance, large depth of fields
◆ High eye-position and extra wide-field eyepieces.
◆ Horizontal axial drive control knobs, easy to operation
◆ Extensively used in mineral specimen researching,precision components assembling, industry productline and weeny objects inspection
◎ ATS300 includes ATS312, ATS313, ATS324
◆ Change magnification by the turret body, orientation precision, excellent parfocal performance
◆ High eye point and extra wide-field eyepieces
◆ Especially be long time used in industry product line
| Zoom driver | ATS100 Series change magnification by knobs ATS300 Series change magnification by the turret |
| Eyepiece | SWH10X high eye point & extra wide-field eyepiece ,FOV Φ23mm |
| Eyetubes | Inclined 45° |
| WD | 105mm |
| Focus range | 50mm(track stand: 100mm) |
| Interpupillary distance adjustment range (10X eyepiece) | 52mm~76mm |
| Diopter adjustment range | ±6 Diopter |
| The holder and the head matching dimension | Φ76mm |
| Distance between the center of the pole and the center of the holder | 140mm |
| Diameter of the pole | Φ25mm |
| Diameter of the center working stage | Φ95mm |
| Illuminators | Optional illumination:5W fluorescent lamp at the bottom; halogen lamp(6V、10W) on the top. |
| Model | Objective | Specification of different eyepiece | |||||||
| SWH10X | SWF15X | SWF20X | SWF30X | ||||||
| Total Mag. | FOV(mm) | Total Mag. | FOV(mm) | Total Mag. | FOV(mm) | Total Mag. | FOV(mm) | ||
| MTS112 MTS312 | 1X | 10X | Φ23 | 15X | Φ17 | 20X | Φ14 | 30X | Φ9 |
| 2X | 20X | Φ11.5 | 30X | Φ8.5 | 40X | Φ7 | 60X | Φ4.5 | |
| MTS113 MTS313 | 1X | 10X | Φ23 | 15X | Φ17 | 20X | Φ14 | 30X | Φ9 |
| 3X | 30X | Φ7.67 | 45X | Φ5.67 | 60X | Φ4.67 | 90X | Φ3 | |
| MTS124 MTS324 |
2X | 20X | Φ11.5 | 30X | Φ8.5 | 40X | Φ7 | 60X | Φ4.5 |
| 4X | 40X | Φ5.75 | 60X | Φ4.25 | 80X | Φ3.5 | 120X | Φ2.25 | |
Optional Accessories:
|
|
Stands | SD1~SD18 |
|
|
Universal stands | U1, U2, U3, U4, U1c, U2c, U3c |
![]() |
Eyepieces | WFH10X, SWF15X, SWF20X, SWF30X |
|
|
Divisional eyepieces | WFH10X-CM0.1XY SWF15X-CM0.05XY SWF20X-CM0.05XY |
|
|
Plane achromatic objectives | PS-W0.5, PS-W0.7, PS-W1.0, PS-WP1.0, PS-W1.5 |
|
|
CCD adapters | C0.3-S、C0.5-S、C1.0-S |
| Digital camera adapter | DT01 | |
| Digital camera adapter | PT02 | |
| 1X CCD adapter with micrometer | CDM1.0
Note: It should be used with CCD adapter together. |
|
|
|
Auxiliary illuminators | ML01, ML02, MLR60, LGY-150Ω |
|
|
Mechanical stage | S7665, S10086
Note: Please explain in advance while the mechanical stage needs to be installed on the stand, the stand needs specially be increased the screw holes. |
Notes: The track stand for AZPS0850 is different from the standard, and identified as”p”, for example, if SD4 used for parallel stereo microscopes, it will be indicated as SD4P.