CM-150 Screen Centering Microscope for Lab Centration Inspection
Instrument Features High accuracy. 15″ per division. Fixed reticle graduation. The reticle graduation of the instrument is always maintained at 15″ per division…
View details →| Model | Detail | Picture | |
| KEL-2000 | For Upright Biological Microscope | 1. Power supply voltage: 220V±10%, AC45—60HZ
2. Output voltage: 36V, power: 50W 3. Temperature setting method: digital display, preset 4. Temperature control range: room temperature -60°C 5. Measurement accuracy: full range ≤±0.2°C 6. System working environment temperature: adaptive room temperature working temperature 7. Heating plate size: 150×125×8mm, aperture: 20×60mm |
![]() |
| KEL-2000A | For Inverted Biological Microscope | 1. Power supply voltage: 220V±10%, AC45—60HZ
2. Output voltage: 36V, power: 50W 3. Temperature setting method: digital display, preset 4. Temperature control range: room temperature -60°C 5. Measurement accuracy: full range ≤±0.2°C 6. System working environment temperature: adaptive room temperature working temperature 7. Table size: φ110/φ108mm |
![]() |
| KEL-2000B | For Stereo Microscope | 1. Power supply voltage: 220V±10%, AC45—60HZ
2. Output voltage: 36V, power: 50W 3. Temperature setting method: digital display, preset 4. Temperature control range: room temperature -60°C 5. Measurement accuracy: full range ≤±0.2°C 6. System working environment temperature: adaptive room temperature working temperature 7. Workbench size: 165×130×8mm, aperture: φ38mm |
![]() |
| KEL-2000C | For High Precision Sperm Microscope | 1. Power supply voltage: 220V±10%, AC45—60HZ
2. Output voltage: 36V, power: 50W 3. Temperature setting method: digital display, preset 4. Temperature control range: room temperature -60°C 5. Measurement accuracy: full range ≤±0.1°C 6. System working environment temperature: adaptive room temperature working temperature |
![]() |
| X-4 | Melting Point Detector | 1. Input power: AC 220V ±10% 45-60HZ
2. Temperature range: room temperature—300°C 3. Power consumption: 60W 4. The maximum temperature of the outer body of the heating stage: when the heating body is 300°C; when the room temperature is 25°C, it is ≤70°C 5. Accuracy: Measurement accuracy: full range ≤ ± 0.2% 6. System fluctuation: ±1°C 7. Specifications of heating stage: shape φ108mm×thickness 10.5mm Thermal body φ32mm×thickness 8.5mm Clear hole φ4.0mm, mass 215g 8. Instrument size: 176×160×108 (MM), mass 2.38kg |
![]() |
| X-4H | Melting Point Detector | 1. Input power: AC 220V ±10% 45-60HZ
2. Temperature range: room temperature—300°C 3. Power consumption: 60W 4. The maximum temperature of the outer body of the heating stage: when the heating body is 300°C; when the room temperature is 25°C, it is ≤70°C 5. Accuracy: Measurement accuracy: full range ≤ ± 0.2% 6. System fluctuation: ±1°C 7. Specifications of heating stage: shape φ108mm×thickness 10.5mm Thermal body φ32mm×thickness 8.5mm Clear hole φ4.0mm, mass 215g 8. Instrument size: 176×160×108 (MM), mass 2.38kg |
![]() |
| X-5 | Microscope precision thermostat Golden Terrace
|
1. Input power: AC 220V ±10% 45-60HZ
2. Temperature range: room temperature—450°C 3. Power consumption: 60W 4. The maximum temperature of the outer body of the heating stage: when the heating body is 360°C; when the room temperature is 25°C, it is ≤70°C 5. Accuracy: Measurement accuracy: full range ≤ ± 0.2% 6. System fluctuation: ±1°C 7. Specifications of heating stage: shape φ108mm×thickness 10.5mm Thermal body φ32mm×thickness 8.5mm Clear hole φ4.0mm, mass 215g |
![]() |
| KER3101-500S | For Polarization Microscope | 1. Input power: AC 220V ±10% 45-60HZ
2. Temperature range: room temperature—500°C 3. The range of heating/cooling speed can be set: 1-60 seconds/℃ (the heating and cooling are the same as the knob) 4. Temperature rise/fall control: automatic recognition conversion, one-twist setting. 5. The maximum temperature of the outer body of the heating stage: when the heating body is 500°C; when the room temperature is 25°C, it is ≤70°C 6. Accuracy: Measurement accuracy: full range ≤ ± 0.5% 7. System fluctuation: ±1°C 8. Immediate constant temperature response time: ≤0.01 seconds |
![]() |
| X-500S | Microscope precision thermostat Golden Terrace
|
1. Input power: AC 220V ±10% 45-60HZ
2. Temperature range: room temperature—500°C 3. Power consumption: 60W 4. The maximum temperature of the outer body of the heating stage: when the heating body is 360°C; when the room temperature is 25°C, it is ≤70°C 5. Accuracy: Measurement accuracy: full range ≤ ± 0.2% 6. System fluctuation: ±1°C 7. Specifications of heating stage: shape φ108mm×thickness 10.5mm Thermal body φ32mm×thickness 8.5mm Clear hole φ4.0mm, mass 215g 8. Instrument size: 176×160×108 (MM), mass 2.38kg |
![]() |
| KER5100 | High-precision two-way precision thermostat (hot and cold stage)
|
1. Temperature range of constant temperature table: minus 50°C. (The lowest temperature depends on the temperature of the heat exchange fluid. When the heat exchange flow is at room temperature of 18 °C, it can reach minus 30 °C.
2. Controller input power: AC 220V ±10% 45-60HZ. 3. Working power supply of constant temperature table: DC 0-12V 0-6A automatic adjustment. 4. Accuracy: Measurement accuracy: full range≦±0.2% 5. System fluctuation: ±0.1°C Display scale: 0.1°C 6. Rise/fall speed function: bidirectional linear. 7. The heating/cooling speed range can be set: 1-36 seconds/0.1 ℃, the same button setting, automatic conversion. 8. Immediate constant temperature response time: ≦0.1 seconds. 9. Heating/cooling status judgment: automatic. 10. Heating/cooling crossover out of control zone: ≦±1.5℃. |
![]() |